RF
SHIELDED ENCLOSURE
FOR UHF /
MICRO WAVE SHIELDING
.files/image002.gif)
Features
·
This is a double-layer galvanized steel panel
shielded unit.
·
New shielding technology to achieve great
improvement.
·
Suitable for plants producing RF products,
quality control during production and are ideal for R&D laboratories.
· Special design to meet customer requirements.
·
All power lines are filtered by newly designed Japanese RF suppression
filters to give better shielding effect.
·
Specially made copper finger strips are used for door edges to provide
good RF-tight.
·
I/O Signals
penetration unit can be made to order.
RF
Shielded Room is built to reduce most RF interference which lowers performance
of electronic equipment in your work place. Our shielded rooms are reliable and
well developed to suit your needs. There are a wide range of shielded rooms
with different sizes for use in Production Plants, R & D Labs, and
Communication Services Centers.
YT series is a double shielded room and all materials used are zinc plated steel for protection against corrosion damages. The door edges are shielded by specially made copper finger strips for better electrical contact to prevent RF leak-in.
Please do not hesitate to give us your custom designs. We will make the rooms to satisfy your requirements.
L
x W x H
|
Internal (app) |
|
6’ x 6’ x 6’ 9” (1.83 x 1.83 x 2.05 M) |
5.5’ x 5.5’ x 6.1’ (1.68 x 1.68 x 1.85 M) |
|
6’ x 9’ x 6’ 9” (1.83 x 2.74 x 2.05 M) |
5.5’ x 8.5’ x 6.1’ (1.68 x 2.59 x 1.85 M) |
|
9’ x 9’ x 6’ 9” (2.74 x 2.74 x 2.05 M) |
8.5’ x 8.5’ x 6.1’ (2.59 x 2.59 x 1.85 M) |
Any custom sizes are welcome.
Performance for 1 GHz Series
|
Frequency |
Attenuation |
Field |
|
1 MHz |
> 85 dB |
Electric
|
|
10 MHz |
> 85 dB
|
Electric |
|
100 MHz |
> 85 dB |
Plane wave |
|
400 MHz |
> 85 dB |
Plane wave |
|
1 GHz |
> 80 dB |
Plane wave |
Performance for 2.4 GHz Series
|
Frequency |
Attenuation |
Field |
|
1 MHz |
> 85 dB |
Electric
|
|
10 MHz |
> 85 dB
|
Electric |
|
100 MHz |
> 85 dB |
Plane wave |
|
400 MHz |
> 85 dB |
Plane wave |
|
1 GHz |
> 85 dB |
Plane wave |
|
2 GHz |
> 70 dB |
Plane wave |
.files/image004.jpg)
Although the electronic test equipment is shielded during the electronic
product testing process, interference signals will leak in through the power
lines (Fig.1). Hence, a symmetrical π- Type low pass
filter must be installed where the power lines enter the shielded room.
.files/image007.jpg)
.files/image008.jpg)
Capacitors
are inserted between the line and shielding as shown in Fig.2. When the FILTER
is installed, a difference of potential is produced between the ground and shielding.
Consequently, there is a danger of electric shock if the shielding is touched.
Therefore, the shielding must be securely grounded at all times. (Fig.3)
Connection for shielded room electric supply
.files/image010.gif)
YT2G
Series shielding effect (2.4 GHz)
.files/image012.jpg)
Performance
tests are in compliance with MIL-STD-285 test procedure